For a typical 12-volt landscape lighting system, choose two-conductor, stranded copper landscape lighting cable rated for direct burial wherever the wire will be in the ground. 12/2 is a practical starting point for a main run. A short branch serving a few small LEDs may work well with 14/2 or 16/2. A long feed carrying several powerful uplights may need 10/2.

To choose between them, you need three things from your own yard: the distance the cable will travel, the electrical load it will carry, and the voltage your fixtures need. Where you place the lights matters, too. Six lights grouped around a tree 100 feet away put a different demand on the wire than six lights spaced along a 100-foot walkway. That difference can change which spool you should buy.

 

Read the Cable Label Before You Compare Gauges

On a reel marked 12/2, the first number is the American Wire Gauge, or AWG, of each conductor. The second number tells you the cable contains two conductors. A smaller AWG number means a thicker conductor, so 12/2 contains more copper than 14/2 of the same length and construction. Both can be used in a 12-volt system when the equipment accepts that size.

14 AWG vs 12 AWG Copper Wire Comparison

Look for three details on the reel or specification sheet:

  • Stranded copper conductors. The strands make the cable flexible enough to follow a curved bed or enter a fixture base. Copper-clad aluminum, sometimes marked CCA, has higher resistance than copper of the same gauge. A wire-size chart calculated for copper will overestimate what the same gauge of CCA can deliver.
  • A direct-burial rating. Ordinary indoor lamp cord can carry the same 16/2 marking as landscape cable. The installation rating tells you whether the insulation is suitable for prolonged contact with soil and moisture.
  • Sunlight resistance where the cable is exposed. Check this if any part of the route comes above ground, such as the short section leading up to a wall-mounted transformer.

Also check the wire sizes accepted by the transformer terminals and fixture connectors. A reel of heavy cable is a poor purchase if the equipment at either end cannot accept it.

 

Measure the Route and Add Up the Load on Each Run

Start at the transformer and walk the route the cable will actually follow. Include the turn around a patio, the rise to a raised planter, and the distance between fixtures. A tree that stands 65 feet from the house may take 85 feet of cable to reach. If a sizing chart asks for one-way distance, enter 85 feet. The chart already accounts for the return conductor.

Next, group the lights by the cable that supplies them. When recording the wattage of each landscape light, use the actual electrical input printed on the fixture or lamp. A 5-watt LED advertised as a “35-watt equivalent” goes on your list as 5 watts. The equivalent figure describes its approximate light output.

For AC-powered LED fixtures, use the rated input current or the volt-ampere figure, shown as VA, when available. LED drivers can draw more current than a watts-only calculation suggests. For example, a fixture labeled 5 W, 6 VA at 12 V AC draws about 0.5 amp at its rated voltage. Six of those fixtures put approximately 3 amps on the cable feeding the group. For a DC fixture, divide its rated input watts by its rated volts to estimate current.

Size each cable for the lights it serves. If the front path and rear garden have separate cables from the transformer, calculate each run individually, then check their combined load against the transformer rating. Also check the current limit for each output and the wire sizes permitted by its circuit protection. A transformer can have capacity to spare while the last light on a long branch still receives too little voltage.

Landscape Lighting Wire Gauge by Wattage and Run Length

To read the chart, find the combined wattage of the fixtures on one cable run across the top. Then find the length of that run, in feet, down the left side. The number where the column and row meet is the wire gauge in AWG. For example, the 40-watt column and the 200-foot row meet at 12 AWG.

Watts 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200
Feet  
40 16 16 16 16 16 16 16 16 16 14 14 12 12 12 12 12 12 12 12 12
60 16 16 16 16 16 16 16 16 14 14 14 12 12 12 12 12 12 12 12 10
80 16 16 16 16 16 16 14 14 14 14 14 12 12 12 12 10 10 10 10 10
100 16 16 16 16 14 14 14 14 14 12 12 12 10 10 10 10 10 10 10 8
120 12 12 12 12 12 12 12 12 12 12 10 10 10 10 10 8 8 8 8 8
142 12 12 12 12 12 12 12 12 10 10 10 10 10 8 8 8 8 8 8 8
160 12 12 12 12 12 12 12 10 10 10 10 8 8 8 8 8 8 8
180 12 12 12 12 12 12 10 10 10 10 8 8 8 8 8 8
200 12 12 12 12 12 12 10 10 10 8 8 8 8 8 8
220 12 12 12 12 12 10 10 10 8 8 8 8 8
240 12 12 12 12 10 10 10 8 8 8 8 8
260 12 12 12 12 10 10 10 8 8 8 8
280 12 12 12 10 10 10 8 8 8 8
300 12 12 12 10 10 10 8 8 8 8
320 12 12 10 10 10 8 8 8 8
340 12 12 10 10 8 8 8 8 8
360 12 10 10 10 8 8 8 8

Use the chart to identify a starting gauge. Voltage drop still occurs below 80% of a cable’s rated current. On a 200-foot one-way run of 12 AWG copper, a steady 3.33 A load at the far end would produce an estimated drop of 2.4 V, leaving about 9.6 V at the lights from a 12.0 V supply.

For AC LED fixtures, check the input current or volt-ampere (VA) rating on the fixture label before using a watts-based chart. A fixture rated 5 W and 6 VA at 12 V AC draws about 0.5 A at its rated voltage. That current is what you need for the voltage-drop calculation.

 

What Changes Between 16/2, 14/2, 12/2, and 10/2?

Consider six tree uplights grouped at the far end of a 100-foot cable. Together they draw approximately 3 amps. Suppose the transformer supplies 12.0 volts under load and the fixtures in this example need at least 11.0 volts. That gives you 1.0 volt of allowable loss between the transformer and the lights.

Low Voltage Wire for Landscape Lighting

The strand count of stranded copper wire is not determined by AWG size alone. It varies depending on the individual strand diameter, stranding configuration, and manufacturer.

The following estimates use published resistance values for stranded copper landscape cable at 77°F. They hold current constant and exclude losses in connectors.

Copper cable Resistance per conductor Estimated drop over the 100-foot run Estimated voltage at the lights
16/2 4.487 Ω per 1,000 ft 2.69 V 9.31 V
14/2 2.814 Ω per 1,000 ft 1.69 V 10.31 V
12/2 1.774 Ω per 1,000 ft 1.06 V 10.94 V
10/2 1.111 Ω per 1,000 ft 0.67 V 11.33 V

Voltage-drop estimates use the conductor resistance values at 77°F in Table 1 of the cable specification (PDF).

For this group of uplights, 10/2 is the best fit among the four sizes shown. The estimate for 12/2 falls just below the fixtures’ minimum. With 10/2, the estimate leaves about a third of a volt above that minimum. Use the operating range printed on your own fixtures when making the same comparison.

You can reproduce the estimate using the resistance published for the cable you plan to buy:

Estimated voltage drop = 2 × one-way length in feet × current in amps × resistance in ohms per 1,000 feet ÷ 1,000.

The factor of two counts both conductors. If you use a landscape lighting wire size chart, check its assumed voltage-drop allowance. On a 12-volt system, a chart designed around a 5% drop allows 0.6 volt of loss. A chart built around 10% allows 1.2 volts. Those two charts can recommend different gauges for the same yard.

 

Why the Same 100-Foot Walkway Can Use a Different Gauge

Now take the same six lights and place three at the 50-foot mark and three at the 100-foot mark. Keep the transformer, fixture ratings, and total cable length the same. The first 50 feet still carries the full 3 amps. After the first three fixtures take their share, the last 50 feet carries approximately 1.5 amps.

On 12/2 copper, the first section loses about 0.53 volt and the second loses about 0.27 volt. The last light receives an estimated 11.20 volts. In this layout, 12/2 clears the example’s 11.0-volt minimum. The difference comes entirely from where the lights draw their power.

At the smaller end of the scale, consider four 3 VA path lights grouped just 30 feet from the transformer. Their combined load is about 1 amp at 12 volts. Even if all four sit at the far end, the estimated drop on the same type of 16/2 cable is only 0.27 volt. If the fixtures and transformer accept 16 AWG and the resulting 11.73 volts is within the fixtures’ range, the lighter cable is a reasonable choice.

This is also how to account for future additions. One extra 6 VA uplight at the far end of the original 100-foot, 12/2 run adds about 0.18 volt of loss along that feeder. If you already know where the next light will go, include it in the calculation before the planting bed is finished.

 

When Does Changing the Layout Make More Sense Than Buying Thicker Wire?

A heavier gauge is worth pricing when several fixtures must stay together at the far end of a long feed. If the layout is still flexible, look at where the full load travels. Shortening that shared stretch can save more voltage than changing the final few feet of cable.

  • For a straight path, a single cable with fixtures connected in parallel along it is easy to measure. Calculate each section using the load remaining beyond that point.
  • For a walkway that extends both ways from the house, feeding the middle can give you two shorter branches. Include the combined load on the cable between the transformer and the point where the branches split.
  • For a nearby flower bed and a distant group of trees, separate runs from the transformer let you size each route for its own load. The tree lights then draw their current through their dedicated cable.

A junction or hub is most useful when its location improves the route. If a hub sits 90 feet from the transformer, the first 90 feet still carries the current for every light connected beyond it. Calculate that shared feeder before choosing the wire for the short branches.

 

Verify the Choice Before Covering the Cable

Lay out the cable and make the connections with the transformer switched off and disconnected from power. Once the connections are secure, run all the planned fixtures together at full output. Use a suitable meter on the correct AC or DC voltage setting to check the accessible low-voltage output, the nearest fixture, and the farthest fixture on each branch. Compare the readings with the fixtures’ specified input range. Testing with the lights operating shows what the cable delivers during normal use.

12V AC landscape lighting voltage test

If you have a multi-tap landscape lighting transformer, a higher approved tap raises the voltage for every fixture on that output. Check the nearest light’s maximum as carefully as the farthest light’s minimum. Disconnect power before moving a conductor to another tap, then repeat both measurements.

Once the readings are within range, record the gauge, fixture load, and far-end voltage for each run. If you add a light next season, those three numbers give you a starting point for deciding whether the existing cable can carry it.

 

FAQs

1. Can you splice 12/2 and 14/2 landscape lighting wire together?

Yes, when the lighting system permits both sizes and the connector is listed for the exact number and sizes of conductors being joined. A short 14/2 branch off a 12/2 feeder can work well. Check that the smaller section can carry its downstream load, that the circuit protection is suitable for it, and that its voltage drop fits your allowance. Use a direct-burial-rated connector for a buried splice.

2. How deep should low-voltage landscape lighting wire be buried?

For qualifying landscape lighting circuits of 30 volts or less, 6 inches of cover is a common U.S. residential requirement in ordinary planting areas. Cover is measured from the top of the cable to finished grade. Driveway crossings have different requirements, and the instructions for some listed systems permit shallower placement. Check the locally adopted rules for your route. Before digging, contact 811 and wait for the required utility responses.

For a state-code example, see minimum cover requirements for landscape lighting in the 2025 California Electrical Code, Table 300.5(A), column 5 (PDF).

3. Which wire is positive on low-voltage landscape lighting?

On a conventional two-wire 12 V AC fixture, the supply alternates and the fixture leads are usually interchangeable. Follow any terminal markings on the equipment. On a polarity-sensitive DC fixture, connect positive to positive and negative to negative. A stripe or rib helps identify the same conductor along the cable. Its polarity depends on how you connect it at the power supply.

4. Do you need a permit to install low-voltage landscape lighting?

It depends on the jurisdiction and the scope of work. Some cities exempt low-voltage landscape accent lighting from a permit while still requiring planning review. Adding a new 120-volt circuit for the transformer can also change the requirements. When you contact your local building department, give them the transformer’s output rating and explain whether it will plug into an existing outdoor receptacle.

5. How can you find a broken landscape lighting wire without digging up the whole yard?

Identify which fixtures failed together and inspect their shared accessible connections first. If the evidence points to the buried cable, disconnect power and isolate the suspect section before attaching a compatible wire locator. To locate a break in underground landscape lighting wire, trace from both accessible ends and compare the results with electrical checks on that section. A repeatable fault location gives you a much smaller area to uncover.